瘤内扰流装置在颅内动脉瘤治疗中的研究进展
闭士峻1, 潘鹏宇2, 朱廷准2, 张海峰2, 董玉书2, 高旭2, 梁国标2,()   
  1. 1. 110016 沈阳,北部战区总医院神经外科,全军神经医学研究所;116027 大连,大连医科大学
    2. 110016 沈阳,北部战区总医院神经外科,全军神经医学研究所
  • 收稿日期:2022-07-19 出版日期:2022-12-01
  • 通信作者: 梁国标
  • 基金资助:
    国家自然科学基金面上项目(81971133); 辽宁省“兴辽人才计划”(XLYC2002109); 辽宁省科技民生计划(2021JH2/10300059); 沈阳市科技计划(20-205-4-017)

Advances in intrasaccular flow disruption in the treatment of intracranial aneurysm

Shijun Bi1, Pengyu Pan2, Tingzhun Zhu2, Haifeng Zhang2, Yushu Dong2, Xu Gao2, Guobiao Liang2,()   

  1. 1. Department of Neurosurgery, General Hospital of Northern Theater Command, Institute of Neuromedicine, PLA, Shenyang 110016, China; Dalian Medical University, Dalian 116027, China
    2. Department of Neurosurgery, General Hospital of Northern Theater Command, Institute of Neuromedicine, PLA, Shenyang 110016, China
  • Received:2022-07-19 Published:2022-12-01
  • Corresponding author: Guobiao Liang
引用本文:

闭士峻, 潘鹏宇, 朱廷准, 张海峰, 董玉书, 高旭, 梁国标. 瘤内扰流装置在颅内动脉瘤治疗中的研究进展[J/OL]. 中华脑血管病杂志(电子版), 2022, 16(06): 443-446.

Shijun Bi, Pengyu Pan, Tingzhun Zhu, Haifeng Zhang, Yushu Dong, Xu Gao, Guobiao Liang. Advances in intrasaccular flow disruption in the treatment of intracranial aneurysm[J/OL]. Chinese Journal of Cerebrovascular Diseases(Electronic Edition), 2022, 16(06): 443-446.

瘤内扰流装置是治疗颅内血管分叉部宽颈动脉瘤的一种创新方法,其因释放简捷且不需要双重抗血小板治疗而被关注。目前,临床上共有4种不同类型的瘤内扰流装置用于治疗颅内动脉瘤。既往研究已初步说明瘤内扰流装置的安全性和有效性,随着设备和技术的迅速发展,多种瘤内扰流装置进行了结构优化,适应证也相应地逐渐扩大,进一步研究证明了这些最新装置的安全性和有效性。本文主要对4种瘤内扰流装置最新研究进展进行综述。

Intrasaccular flow disruption is an innovative method of treating intracranial wide-necked bifurcation aneurysms. It has raised widespread concern because it does not need dual antiplatelet therapy. At present, four different types of intrasaccular flow disruptions have been used to treat intracranial aneurysms. Previous studies have preliminarily shown the safety and efficacy of intrasaccular flow disruption. With the rapid development of equipment and technology, various intrasaccular flow disruptions have been optimized, and the indications have been gradually expanded accordingly. Further research has proved the safety and efficacy of these latest devices. The review aims to provide an overview of these devices and summarize the literature on the safety and efficacy of these devices in recent years.

表1 临床上主要应用的4种瘤内扰流装置介绍
图1 瘤内扰流装置实物图。图a为瘤内编织扰流装置,图b为LUNA动脉瘤栓塞系统,图c为Medina线圈系统,图d为 Contour神经血管系统
1
Chen C, Dabhi N, Snyder MH, et al. Intrasaccular flow disruption for brain aneurysms: a systematic review of long-term outcomes [J]. J Neurosurg, 2021: 1-13. Online ahead of print.
2
Gawlitza M, Soize S, Manceau P, et al. An update on intrasaccular flow disruption for the treatment of intracranial aneurysms [J]. Expert Rev Med Devic, 2019, 16(3): 229-236.
3
王奎重, 刘卫东. 颅内动脉瘤瘤内扰流装置Woven EndoBridge的临床应用进展 [J]. 中国脑血管病杂志, 2021, 18(4): 277-282.
4
König I, Maurer C, Berlis A, et al. Treatment of ruptured and unruptured intracranial aneurysms with WEB 17 versus WEB 21 systems [J]. Clin Neuroradiol, 2021, 31(3): 691-697.
5
Dmytriw AA, Diestro JDB, Dibas M, et al. International study of intracranial aneurysm treatment using Woven EndoBridge: RESULts of the WorldWideWEB consortium [J]. Stroke, 2022, 53(2): A121037609.
6
Adeeb N, Dibas M, Diestro JDB, et al. Multicenter study for the treatment of sidewall versus bifurcation intracranial aneurysms with use of Woven EndoBridge (WEB) [J]. Radiology, 2022, 304(2): 372-382.
7
Essibayi MA, Lanzino G, Brinjikji W. Safety and efficacy of the Woven EndoBridge device for treatment of ruptured intracranial aneurysms: a systematic review and meta-analysis [J]. Am J NeuroradioL, 2021, 42(9): 1627-1632.
8
Girot JB, Caroff J, Cortese J, et al. Endovascular treatment of small and very small intracranial aneurysms with the Woven EndoBridge device [J]. Am J Neuroradiol, 2021, 42(7): 1276-1281.
9
Algin O, Corabay S, Ayberk G. Long-term efficacy and safety of WovenEndoBridge (WEB)-assisted cerebral aneurysm embolization [J]. Interv Neuroradiol, 2022: 15910199211060970.
10
Peterson C, Cord BJ. Recurrent and residual aneurysms after Woven EndoBridge (WEB) therapy: what's next? [J]. Cureus, 2021, 13(4): e14404.
11
Goertz L, Liebig T, Siebert E, et al. Woven EndoBridge embolization versus microsurgical clipping for unruptured anterior circulation aneurysms [J]. Neurosurgery, 2021, 88(4): 779-784.
12
Kabbasch C, Goertz L, Siebert E, et al. WEB embolization versus stent-assisted coiling: comparison of complication rates and angiographic outcomes [J]. J Neurointerv Surg, 2019, 11(8): 812-816.
13
Goertz L, Liebig T, Siebert E, et al. Intrasaccular flow disruption with the Woven EndoBridge for narrow-necked aneurysms: a safety and feasibility study [J]. World Neurosurg, 2021, 151: e278-e285.
14
Goertz L, Liebig T, Siebert E, et al. Stent-assisted WEB embolization: aneurysm characteristics, outcome and case report of a WEB delivered through a stent [J]. Acta Neurochir (Wien), 2022, 164(8): 2181-2190.
15
Al Saiegh F, Velagapudi L, Khanna O, et al. Predictors of aneurysm occlusion following treatment with the WEB device: systematic review and case series [J]. Neurosurg Rev, 2022, 45(2): 925-936.
16
Cortese J, Caroff J, Chalumeau V, et al. Determinants of cerebral aneurysm occlusion after embolization with the WEB device: a single-institution series of 215 cases with angiographic follow-up [J]. J Neurointerv Surg, 2022: neurintsurg-2022-018780.
17
Di Caterino F, Primikiris P, Vitale G, et al. Woven EndoBridge device immediate post-detachment tilt with later displacement: case report, rescue techniques, and review of the literature [J]. Interv Neuroradiol, 2020, 26(4): 483-487.
18
Abdelrady M, Dargazanli C, Derraz I, et al. Successful WEBectomy during embolization of temporal arteriovenous malformation-associated flow-related basilar aneurysms [J]. Interv Neuroradiol, 2021: 15910199211057693. Online ahead of print.
19
Ansari S, Zevallos CB, Farooqui M, et al. Optimal Woven EndoBridge (WEB) device size selection using automated volumetric software [J]. Brain Sciences, 2021, 11(7): 901.
20
Caroff J, Cortese J, Girot J, et al. Woven EndoBridge device shape modification can be mitigated with an appropriate oversizing strategy: a VasoCT based study [J]. J Neurointerv Surg, 2022, 14(1): neurintsurg-2020-017232.
21
Piotin M, Biondi A, Sourour N, et al. The LUNA aneurysm embolization system for intracranial aneurysm treatment: short-term, mid-term and long-term clinical and angiographic results [J]. J Neurointerv Surg, 2018, 10(12): e34.
22
Piotin M, Fahed R, Redjem H, et al. The ARTISSE intrasaccular device for intracranial aneurysm treatment: short-term, mid-term and long-term clinical and angiographic results [J]. J Neurointerv Surg, 2021: neurintsurg-2021-017806. Online ahead of print.
23
Aguilar Perez M, Bhogal P, Martinez Moreno R, et al. The Medina Embolic Device: early clinical experience from a single center [J]. J Neurointerv Surg, 2016, 9(1): 77-87.
24
Bhogal P, Brouwer PA, Yeo L, et al. The medina embolic device: karolinska experience [J]. Interv Neuroradiol, 2018, 24(1): 4-13.
25
Turk AS, Maia O, Ferreira CC, et al. Periprocedural safety of aneurysm embolization with the Medina Coil System: the early human experience [J]. J Neurointerv Surg, 2016, 8(2): 168-172.
26
Frölich AM, Nawka MT, Ernst M, et al. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage [J]. PloS One, 2018, 13(2): e191975.
27
Haffaf I, Clarençon F, Shotar E, et al. Medina embolization device for the treatment of intracranial aneurysms: 18 months' angiographic results [J]. J Neurointerv Surg, 2019, 11(5): 516-522.
28
Liebig T, Killer-Oberpfalzer M, Gal G, et al. The safety and effectiveness of the Contour neurovascular system (Contour) for the treatment of Bifurcation aneurysms: the CERUS study [J]. Neurosurgery, 2022, 90(3): 270-277.
29
Akhunbay-Fudge CY, Deniz K, Tyagi AK, et al. Endovascular treatment of wide-necked intracranial aneurysms using the novel Contour Neurovascular System: a single-center safety and feasibility study [J]. J Neurointerv Surg, 2020, 12(10): 987-992.
30
Thormann M, Mpotsaris A, Behme D. Treatment of a middle cerebral artery bifurcation aneurysm with the novel Contour Neurovascular System compatible with 0.021″ catheters [J]. Neuroradiol J, 2022, 35(3): 396-398.
[1] 陆婷, 范晴敏, 王洁, 万晓静, 许春芳, 董凤林. 超声引导下经皮穿刺置管引流对重症急性胰腺炎的疗效及应用时机的选择[J/OL]. 中华医学超声杂志(电子版), 2024, 21(05): 511-516.
[2] 邢颖, 程石. 巨脾外科治疗现状与介入治疗序贯手术策略[J/OL]. 中华肝脏外科手术学电子杂志, 2024, 13(03): 253-258.
[3] 李晓东, 李昂, 马龙, 刘亮, 魏云, 王汉宇. 基底动脉顶端动脉瘤显微手术治疗[J/OL]. 中华神经创伤外科电子杂志, 2024, 10(04): 254-256.
[4] 唐必英, 李钢. 治疗时机对动脉瘤性蛛网膜下腔出血患者预后的影响[J/OL]. 中华神经创伤外科电子杂志, 2024, 10(04): 213-219.
[5] 冯铭, 孙洪涛. 动脉瘤性蛛网膜下腔出血的颅内压监测与管理[J/OL]. 中华神经创伤外科电子杂志, 2024, 10(04): 248-253.
[6] 杨金朔, 吴桥伟, 王春雷, 史怀璋. 脑血管内支架成形术后再狭窄的研究进展[J/OL]. 中华神经创伤外科电子杂志, 2024, 10(03): 174-179.
[7] 李晓东, 王汉宇, 马龙, 刘亮, 魏云, 李昂. 小脑后下动脉瘤的显微手术治疗[J/OL]. 中华脑科疾病与康复杂志(电子版), 2024, 14(05): 318-320.
[8] 赖凌峰, 黄小飞, 丁聪, 周小兵. 血流导向装置治疗血泡样动脉瘤的临床效果分析[J/OL]. 中华脑科疾病与康复杂志(电子版), 2024, 14(03): 166-170.
[9] 牟超鹏, 宗斌, 刘奕, 史美英, 徐杜娟, 冯春光. 经远端桡动脉与经常规桡动脉行急诊冠脉介入诊疗后穿刺部位血肿的对比[J/OL]. 中华临床医师杂志(电子版), 2024, 18(03): 275-282.
[10] 朱洪申, 王思权, 彭靓, 张晓斌, 郑美云, 陈锦华. Glubran-2栓塞治疗鼻咽癌相关难治性鼻出血的临床疗效[J/OL]. 中华介入放射学电子杂志, 2024, 12(04): 333-337.
[11] 陈芳, 王建英, 曹建用, 刘丽, 罗晓琴. 基于分析-设计-开发-实施-评价模式的叙事护理培训在产科预防性介入治疗中的应用[J/OL]. 中华介入放射学电子杂志, 2024, 12(04): 392-396.
[12] 崔斯童, 马骏, 刘亮, 夏加庚, 刘振. 双微导管与支架辅助技术治疗颅内未破裂宽颈分叶状动脉瘤的疗效对比分析[J/OL]. 中华介入放射学电子杂志, 2024, 12(03): 200-205.
[13] 李超迪, 刘娟芳, 闫肃, 秦胜东, 张镐哲, 常琼方, 韩新巍, 张建好. 血管性介入治疗在宫颈癌大出血患者中的临床疗效[J/OL]. 中华介入放射学电子杂志, 2024, 12(03): 217-220.
[14] 周宝林, 刘曦, 谌浩, 王金, 马雪琴. 温敏水凝胶在血管内栓塞治疗中的研究进展[J/OL]. 中华介入放射学电子杂志, 2024, 12(03): 244-249.
[15] 周洪千, 张煜坤, 顾天舒, 胡苏涛, 姜超, 张雪, 张昊, 陶华岳, 刘行, 刘彤, 陈康寅. 既往出血性脑卒中患者行经皮冠脉介入治疗后不良事件的危险因素分析[J/OL]. 中华脑血管病杂志(电子版), 2024, 18(04): 323-329.
阅读次数
全文


摘要


AI


AI小编
你好!我是《中华医学电子期刊资源库》AI小编,有什么可以帮您的吗?